VPT Rad
Chelmsford, MA, United States vptrad.com
VPT Rad provides radiation testing and gamma sterilization services for electronic components used in aerospace, defense, nuclear, and other mission-critical environments. It also supports biomedical product development with small-volume gamma sterilization. The company is based in Chelmsford, Massachusetts, USA.
What they offer
Radiation Testing
Turn-key radiation effects testing for electronic components, including qualification and lot acceptance testing.
Gamma Sterilization
Gamma sterilization for small product R&D and biomedical product development cycles.
Radiation Lot Acceptance Testing (RLAT)
Qualification testing using incremental Cobalt-60 gamma exposures with pre- and post-irradiation electrical characterization.
Radiation Hardness Testing
Expedited testing for discrete, analog, digital, and mixed-signal devices.
Radiation Tolerance Testing
Testing to evaluate device performance under ionizing radiation exposure.
Neutron Displacement Damage Testing (NDD)
Offsite neutron displacement damage testing provided with the University of Massachusetts Lowell.
Single Event Effects (SEE) Testing
Single event effects testing available through monthly trips to multiple heavy ion facilities.
What they work on
- Processes
- Radiation testing · Gamma sterilization · Cobalt-60 gamma irradiation · Total Ionizing Dose (TID) testing · High Dose Rate (HDR) irradiation · Low Dose Rate (LDR) testing · Radiation Lot Acceptance Testing (RLAT) · Neutron Displacement Damage Testing (NDD) · Single Event Effects (SEE) testing · Pre- and post-irradiation electrical characterization
- Equipment
- In-house Cobalt-60 irradiators · Small Volume Gamma Irradiator · Automated test equipment (ATE) systems · Bruker alanine-EPR dosimetry system
- Capacity
- Flexible chamber sizes up to 32” x 32” · Small Volume Gamma Irradiator: 6-inch D x 8-inch H · Dose rates ranging from 10 mrad/s (Si) to 300 rad/s (Si)
- Turnaround
- Short cycle time · Within minutes
Company
- Type
- Test lab
- Sites
- Chelmsford, USA
- Quality
- MIL-STD-883 (Test Method 1019 Conditions A, C and D; Test Method 1017; Test Method 1080) · MIL-STD-750 (Test Method 1019 Conditions A, C and D; Test Method 1017; Test Method 1080) · ESCC 22900 (Radiation test methods compliant to ESCC 22900) · DLA Approved (Radiation and test services laboratory; lab suitability for radiation testing on electronic components) · NIST traceable (Absorbed dose measurements and alanine dosimetry)
- Serves
- Outside of the U.S.
- Address
- 101 Brick Kiln Road, Building 2 Chelmsford, MA 01824 Services Company
- Founded
- 2008
Similar shops
Work here? Claim this listing